1. Disconnect the battery from weight. |
Generator of Bosch
|
|
2. Remove the regulator and check length of brushes which has to be not less than 6 mm. |
3. If necessary replace brushes which fasten the screw or the soldering (to solder no more than 5 sec.). |
Generator of Motorola |
4. Remove the generator. |
5. Unscrew screws and remove the regulator and the brush holder. |
6. Check length of brushes which has to be not less than 6 mm. Brushes change in a set. |